Emergency lighting and exit signs are the kind of building infrastructure everyone assumes works until the one moment it actually needs to — during a power failure, a fire alarm activation, or an evacuation. Because they're rarely tested by anyone other than the compliance contractor and rarely thought about by staff or tenants, non-compliance can sit unnoticed in a building for years without anyone realising the system has quietly stopped working.
Voltas Electrical & Airconditioning carries out emergency lighting and exit sign testing and compliance work across commercial and public buildings in Adelaide (BLD 274739 · PGE 265145 · AU 61210). Our electrical installation team handles both new system installation and ongoing compliance testing for existing buildings. This guide covers what AS 2293 requires, the testing cycle, common failure points, and where responsibility sits between building owners and tenants.
The Legal Requirement: AS 2293
Emergency lighting and exit signage in Australian commercial and public buildings is governed by the AS 2293 series of standards, which sets out design, installation, and — critically for ongoing compliance — testing and maintenance requirements. Almost any building open to the public or used as a workplace with more than a handful of occupants requires a compliant emergency lighting and exit sign system, generally as a condition of its building approval and its ongoing Essential Safety Provisions certification managed through local council and the Fire and Emergency Services requirements in South Australia.
This isn't a one-off installation obligation. AS 2293 requires the system to be tested on an ongoing schedule for the life of the building, and it's this ongoing testing requirement that catches many building owners out, particularly on older properties where the system was compliant at installation but has never been formally tested since.
The Testing Cycle: Six-Monthly and Annual
AS 2293 sets out a layered testing regime. A six-monthly discharge test checks that each emergency light and exit sign switches correctly to battery backup when mains power is interrupted, and that the light output meets the minimum standard. An annual test goes further, verifying the battery can sustain the required emergency duration — generally 90 minutes — under full discharge, which is the scenario that actually matters during a real evacuation lasting longer than a brief power blip.
Every test must be logged in a compliance record (commonly a logbook or, increasingly, a digital compliance record) kept on site and available for inspection. This record is what demonstrates compliance to a building certifier, insurer, or fire safety auditor — a system that's actually working but has no test record to prove it is still technically non-compliant on paper.
Not sure when your building's emergency lighting was last tested?
Get a Same-Day QuoteCommon Compliance Failures We Find
A handful of issues account for most of the compliance failures found during inspections of existing Adelaide buildings. Batteries that have degraded and no longer hold sufficient charge for the full 90-minute duration are extremely common, particularly in systems more than 5-7 years old, since emergency lighting batteries have a finite service life regardless of how well the fitting itself has been maintained. Exit signs obscured by later fit-out changes — a partition wall, new signage, or stock shelving installed after the emergency lighting design was completed — are another frequent finding, and one that's often invisible until someone actually checks sightlines from every point in the building.
We also regularly find fittings that have simply never been tested since installation, especially in older strata-titled commercial buildings where responsibility for common-area compliance has fallen through the cracks between multiple tenants and an offsite body corporate manager. A commercial electrical compliance audit is the most reliable way to surface all of these issues in one pass rather than discovering them individually.
Consequences of Non-Compliance
Beyond the obvious safety risk during an actual emergency, non-compliant emergency lighting carries real regulatory and financial consequences. It can prevent a building from obtaining or renewing its annual fire safety or Essential Safety Provisions certification, which in turn can affect a building's ability to legally operate or be leased. Non-compliance discovered after an incident — even one unrelated to the emergency lighting itself — can also affect insurance claims and create serious liability exposure for the responsible party if it's shown the system had been neglected.
None of this is meant to be alarmist; the actual fixes for most compliance gaps we find are inexpensive — a battery replacement, an exit sign relocation, or catching up on a lapsed testing schedule. The risk comes specifically from not knowing there's a gap at all.
Building Owner vs Tenant Responsibility
Responsibility for emergency lighting compliance is usually set out in the lease, but the default position in most commercial arrangements is that the building owner or landlord is responsible for base building emergency lighting and exit signage — the systems installed as part of common areas, stairwells, and core building infrastructure. Tenants typically become responsible for any additional emergency lighting or signage installed as part of their own fit-out, particularly if that fit-out has altered sightlines to existing exit signs or added new escape routes.
Multi-tenant and multi-site businesses should treat this as part of their broader compliance planning rather than assuming it's automatically covered by the landlord — our guide on multi-site business electrical compliance covers how to track this across several locations without gaps falling between tenant and landlord obligations.
Setting Up a Compliance Testing Contract
Given the mandatory six-monthly and annual cycle, most building owners and facility managers find it far more practical to set up an ongoing compliance testing contract than to manually schedule and track each test. A typical Adelaide compliance contract for a small-to-medium commercial building runs from roughly $300-$800 per year depending on the number of fittings and exit points, covering both the six-monthly and annual tests plus compliance record-keeping. This is a small cost relative to the risk of a lapsed system going unnoticed, and it removes the administrative burden of remembering to book it yourself. We provide ongoing compliance testing contracts for commercial buildings across Adelaide, including sites around Port Adelaide and Noarlunga Centre.
Frequently Asked Questions
How often must emergency lighting be tested under AS 2293?
AS 2293 requires a six-monthly discharge test of the emergency lighting and exit sign system, along with more frequent visual checks, and a full annual test that verifies the system can sustain the required duration (generally 90 minutes) on battery backup alone. Testing must be logged in a compliance record kept on site.
Who is responsible for emergency lighting compliance, landlord or tenant?
This depends on the lease, but responsibility is most commonly assigned to the building owner or landlord for base building emergency lighting systems, while tenants may be responsible for any additional signage or lighting installed within their own fit-out. It's important the lease clearly states who is responsible, since non-compliance risk sits with whoever is named.
What happens if a building fails an emergency lighting compliance check?
Non-compliance can result in the building failing to obtain or renew its annual Essential Safety Provisions certification, potential fines, and in a worst-case scenario, serious legal and insurance exposure if an emergency lighting failure contributes to injury during an evacuation. Most issues found during testing are minor and inexpensive to fix if caught early.
How much does emergency lighting compliance testing cost per year?
A typical Adelaide compliance contract for a small-to-medium commercial building runs roughly $300-$800 per year in 2026, covering the required six-monthly and annual tests plus compliance record-keeping. Larger buildings with more fittings and exit points will cost more.
Stay Ahead of Your Emergency Lighting Compliance Obligations
AS 2293 testing, repairs, and compliance contracts available for commercial buildings across Adelaide and South Australia.
This article is based on AS 2293 standards and Voltas' own trade experience with commercial compliance testing across Adelaide.
Disclaimer: This article is provided as general information and guidance only. It draws on publicly available sources, government and industry publications (referenced where relevant), and Voltas Electrical Adelaide's own trade experience — it is not personalised advice for your specific property and does not replace a licensed, on-site assessment. Regulations, pricing, and product or brand details can change over time, so please independently verify anything relevant to your decision and seek your own professional advice before acting. To the fullest extent permitted by law, Voltas Electrical Adelaide accepts no responsibility or liability for any loss, damage, or other outcome arising from reliance on the information in this article. Where this article refers to a same-day or obligation-free quote or assessment, that refers to the quote or assessment itself — a site visit to a property well outside our normal Adelaide metro service area may incur a travel or call-out fee, as set out in our Terms & Conditions, which also has full details on the points above.