Walk into most Adelaide offices, shops and warehouses — from a Noarlunga Centre retail strip to a north-side industrial estate — on a 35°C February afternoon and you'll find the air conditioner set somewhere between 19°C and 21°C — colder than it needs to be, often left running well after the last person's gone home, and frequently cooling a stockroom or storage area nobody's set foot in all day. None of that makes the space more comfortable during actual trading hours. It just adds cost to a power bill that's already one of the bigger line items for a cooling-dependent Adelaide business over summer.
Voltas Electrical & Airconditioning has installed and serviced commercial air conditioning across Adelaide since 2010, holding electrical licence BLD 274739, plumbing/gasfitting licence PGE 265145 and refrigerant handling licence AU 61210. Getting a system running efficiently — not just running — is a big part of what we're asked to help with once a business's summer power bills come in, and the fix is usually a combination of three things: the right setpoint, a proper schedule, and zoning that matches how the space is actually used.
What's the actual optimal thermostat setting for a business?
The Australian Government's own energy-efficiency guidance, published at energy.gov.au, recommends a summer cooling setpoint in the mid-to-upper 20s Celsius — generally around 25-27°C — as the practical balance between comfort and running cost. For a busy, customer-facing commercial space with more people and more equipment adding heat than a typical home, many Adelaide businesses run a little cooler than the household recommendation to stay comfortable — commonly somewhere in the 23-26°C range for the occupied cooling season — without tipping into the wasteful territory of the high teens or low 20s that a lot of thermostats get left sitting at by default.
There's no single "correct" number that suits every business — a busy café kitchen, a retail shopfront with constant door traffic, and a quiet back-office all carry different heat loads. What matters is picking a genuine setpoint in that 23-26°C band for the occupied space and sticking to it, rather than letting whoever's nearest the wall unit knock it down another two degrees every time they feel warm.
Why each 1°C actually changes your running cost
This is the part that surprises most business owners: the jump from, say, 24°C to 21°C doesn't cost "a bit more" — it compounds. Per energy.gov.au, each degree of extra cooling in summer increases air conditioning energy use by roughly 5-10%. Push a system three degrees colder than it needs to be and you can realistically be looking at 15-30% more energy going into cooling the same space, for a comfort difference most staff and customers won't actually notice walking through the door.
The reason is straightforward refrigeration mechanics: the bigger the gap between the outdoor temperature and your indoor setpoint, the harder the compressor has to work, and the longer it runs per cooling cycle to hold that colder target. On a 38°C Adelaide summer day, the difference between holding 26°C and holding 21°C is a lot more compressor run-time than the five-degree gap on the thermostat dial suggests — which is exactly why that setting matters so much more in summer than most people assume.
Not sure if your commercial system is actually sized and set up to run efficiently at a sensible setpoint? We can assess it and recommend fixes specific to your space.
Get a Same-Day QuoteTimers and scheduling: stop paying to cool an empty building
An office, shop or warehouse with nobody in it doesn't need to be held at a comfortable temperature. It's one of the most common — and most avoidable — sources of wasted commercial cooling cost: a system left running overnight, over a weekend, or through a public holiday because nobody manually switched it off, or because someone forgot to reset it after an after-hours event.
A programmable timer or a smart thermostat schedule fixes this without relying on anyone remembering. Most commercial systems — whether a multi-split, ducted, or VRF/VRV setup — support a weekly schedule that ramps the system down (or off entirely) outside trading hours and brings it back to the comfortable setpoint shortly before staff or customers arrive, rather than starting from a cold building at 6am and burning extra energy on the initial pull-down. For a business trading Monday to Saturday with genuine downtime overnight and on Sundays, that scheduling alone can represent a meaningful share of total cooling hours removed from the bill across a year, simply by not conditioning space nobody's using.
Zoning: don't cool space nobody's occupying
The other side of "don't cool an empty building" is "don't cool an empty part of an occupied building." A ducted or multi-head commercial system split into independently controlled zones can hold the customer floor or main office area at the target setpoint while turning down or switching off a storeroom, a rarely-used meeting room, a stockroom, or an after-hours-only section — instead of one thermostat forcing the whole tenancy to run at the same setting regardless of who's actually in each part of it.
This matters more for commercial tenancies than most homes, because commercial floor plans often mix constantly-occupied space (the shop floor, the main office) with intermittently-used space (a storeroom, a boardroom booked twice a week, a loading dock) under one roof. If your business runs more than one location, it's worth standardising the setpoint, schedule and zoning approach across sites the same way you'd standardise electrical compliance across a multi-site business — otherwise each store or office ends up on its own inconsistent settings. We've covered how zoning works on a ducted system in more depth in our dedicated ducted air conditioning zoning guide — the same underlying principle applies whether it's a home with a rarely-used spare room or a business with a storeroom that doesn't need to sit at 24°C all day.
Getting the setup right matters more than the setting itself
A thermostat schedule and a sensible setpoint only save money if the system behind them is actually sized and configured to support them. A commercial system that's undersized for the space will end up running flat-out regardless of what the thermostat says, because it's straining to reach the setpoint rather than comfortably cycling around it — and a system that's the wrong type for the floor plan (a single-zone unit trying to cover a space that genuinely needs independent zones) can't deliver the scheduling and zoning benefits described above at all. If your business is planning a new air conditioning installation or replacing an ageing system, our guide on how to size a commercial air conditioning system covers how that sizing decision is actually made, and our commercial air conditioning fitout guide covers what's involved in specifying and installing the right system in an office or retail tenancy from the outset — often alongside the same tenancy's broader office electrical fit-out checklist.
For an existing system that's simply set up poorly — no scheduling, no zoning, a setpoint that's colder than it needs to be — the fix is often a configuration and controls job rather than a full system replacement. As a licensed Adelaide electrical and air conditioning contractor offering same-day appointments and 24/7 emergency response, Voltas can assess an existing commercial system's controls as part of a broader commercial air conditioning maintenance visit and recommend the changes that will actually move the needle on running cost, rather than guessing.
Frequently Asked Questions
What is the best thermostat setting for a business air conditioner in summer?
energy.gov.au recommends a summer cooling setpoint in the mid-to-upper 20s Celsius, generally 25-27°C, as the practical balance between comfort and running cost. Many commercial buildings run closer to 23-26°C for a busy customer-facing space, but every degree colder below that range adds meaningfully to the power bill for a marginal comfort gain.
How much does each degree on the thermostat actually cost a business?
According to energy.gov.au, each degree of extra cooling in summer increases air conditioning energy use by roughly 5-10%. Across a full commercial cooling season that compounds quickly, so a system left running at 20°C instead of 24°C can be using noticeably more power for a difference most staff and customers won't even notice.
Does turning the air conditioner off overnight and on weekends actually save money?
Yes. An empty office, shop or warehouse doesn't need cooling, and a programmable timer or smart thermostat schedule stops the system running through unoccupied nights and weekends automatically, rather than relying on someone remembering to switch it off. This is one of the most reliable ways to cut a business's cooling costs without touching comfort during trading hours.
What is zoning and how does it reduce commercial cooling costs?
Zoning splits a ducted or multi-head commercial system into independently controlled areas, so a storeroom, unused meeting room or after-hours section of a building isn't cooled at the same rate as the occupied space. Because a system isn't paying to condition air in rooms nobody is using, zoning can meaningfully cut running costs, particularly in a tenancy with mixed occupancy patterns across the day.
Want your commercial system set up to actually save money?
We can assess your setpoint, scheduling and zoning and recommend changes that lower your running costs without touching comfort during trading hours.
Sources referenced for the thermostat setpoint and per-degree running cost guidance include the Australian Government's energy.gov.au heating and cooling guidance.
Disclaimer: This article is provided as general information and guidance only. It draws on publicly available sources, government and industry publications (referenced where relevant), and Voltas Electrical Adelaide's own trade experience — it is not personalised advice for your specific property and does not replace a licensed, on-site assessment. Regulations, pricing, and product or brand details can change over time, so please independently verify anything relevant to your decision and seek your own professional advice before acting. To the fullest extent permitted by law, Voltas Electrical Adelaide accepts no responsibility or liability for any loss, damage, or other outcome arising from reliance on the information in this article. Where this article refers to a same-day or obligation-free quote or assessment, that refers to the quote or assessment itself — a site visit to a property well outside our normal Adelaide metro service area may incur a travel or call-out fee, as set out in our Terms & Conditions, which also has full details on the points above.