If you've had a few quotes for a new split system lately, you may have noticed the paperwork lists "R32" as the refrigerant rather than "R410A" — the gas that's been standard in Australian air conditioners for close to two decades. This isn't a brand quirk or a cost-cutting swap, and it's a separate question entirely to whether the unit runs an inverter or fixed-speed compressor. It's the result of a deliberate, government-mandated shift in what refrigerants are allowed into new equipment sold in Australia, and it's worth understanding before you sign off on an install.
As a licensed Adelaide air conditioning and electrical business (BLD 274739 · PGE 265145 · AU 61210) that's installed and serviced hundreds of split systems across both refrigerant generations, we get asked about R32 several times a week — usually "is it safe?" and "does my old system need replacing?" Short answers: yes, and no. The rest of this article covers the actual regulation behind the change and what it does and doesn't mean for your home.
Why Australia is phasing down R410A
Australia's refrigerant phase-down runs under the Ozone Protection and Synthetic Greenhouse Gas Management Act 1989, administered by the Department of Climate Change, Energy, the Environment and Water (DCCEEW). It works through a shrinking import quota on hydrofluorocarbon (HFC) refrigerants — gases like R410A and R134a that don't damage the ozone layer but do carry a high global warming potential (GWP), meaning a leaked kilogram traps far more heat in the atmosphere than an equivalent amount of CO2. The total volume of high-GWP HFCs allowed into the country each year has been stepping down since 2018, on a track toward 15% of the original baseline by 2036.
That quota squeeze alone was already pushing manufacturers toward lower-GWP alternatives. Then, on 1 July 2025, DCCEEW's rules went further: it became illegal to import or manufacture small split and multi-head air conditioning systems — broadly, units with a standard refrigerant charge of 2.6kg or less designed for home comfort cooling and heating — if they're designed to run on a refrigerant with a GWP over 750. R410A, at a GWP of roughly 2,088, sits well above that line, so new equipment built around it can no longer legally enter the Australian market. R134a (GWP 1,430) is caught the same way.
R32, by contrast, has a GWP of about 675 — under the 750 threshold — which is why it, along with genuinely low-GWP gases like R290 (propane), is the refrigerant manufacturers standardised on for residential split systems well ahead of the deadline. By the time the ban took effect, most major brands sold in Adelaide — Daikin, Mitsubishi Electric, Fujitsu General, Panasonic and others among the 20+ trusted AC brands we install and service — had already transitioned the bulk of their split-system range to R32.
Quoting a new split system and want the refrigerant, sizing and brand explained in plain English before you commit?
Get a Same-Day QuoteWhat A2L flammability actually means for your home
The other detail worth understanding is R32's safety classification. Under AS/NZS ISO 817 — the Australian Standard for refrigerant safety classification — R32 is rated A2L: "A" for lower toxicity, "2L" for lower flammability. In plain terms, R32 is mildly flammable under specific conditions (a concentrated leak near an ignition source in a poorly ventilated space), unlike R410A, which is non-flammable.
That classification is exactly why correct, licensed installation matters more with R32 than it did with R410A. A properly designed R32 system accounts for room size versus refrigerant charge, correct pipe joining and pressure-testing, appropriate indoor unit placement, and leak-detection practice during commissioning — all requirements built into the training and equipment licensing that Australian refrigerant technicians must hold. Handled this way, an R32 split system carries no meaningful extra day-to-day risk for an Adelaide household, whether it's sized for a single room or as part of a larger multi-zone air conditioning setup. The risk profile A2L describes is a handling and installation-quality issue, not a reason to avoid R32 systems altogether — every major manufacturer builds their R32 units to run safely for the life of the equipment when installed to standard.
This is also why DIY refrigerant work, already illegal without the right licence and Refrigerant Trading Authorisation, is a firmer line with R32 than ever. If you're weighing up who to book for the install itself, our own guide on choosing the right air conditioner brand in Adelaide covers what to check for beyond the refrigerant question — energy rating, local parts support and warranty terms all matter just as much.
Does this affect the R410A air conditioner you already own?
No — and this is the point most homeowners get wrong. The phase-down and the 1 July 2025 restrictions govern what can be newly imported or manufactured for sale in Australia. They don't reach backward to touch equipment that's already installed and running in your Adelaide home. If your current split system uses R410A, it remains completely legal to keep, service, and repair for the rest of its working life — see our guide to extending your air conditioner's lifespan for how to get the most out of it in the meantime.
Where this does matter is servicing. R32 is not a drop-in substitute for R410A — the two gases have different pressure and performance characteristics, and refrigerant charging rules that took effect on 1 January 2020 make it illegal to charge equipment with anything other than the refrigerant it was designed for. If your existing R410A system develops a slow leak and needs a top-up, it gets regassed with R410A, not switched over to R32. Our air conditioner regas guide walks through the warning signs that a system's low on refrigerant and what a proper regas involves — that process is unchanged by any of this. R410A stock remains available for servicing existing units; it's only new equipment manufacture and import that the ban targets.
The practical upshot: if your current air conditioner is working fine, there's no compliance reason to replace it early. The R32 conversation only becomes relevant when you're due for a new installation — whether that's a first split system, a replacement for an ageing unit, or an addition to a Adelaide home that's just had a granny flat or extension built. At that point, R32 (or another low-GWP gas the manufacturer has moved to) is simply what comes standard, the same way every new car now ships with a different emissions rating to one from a decade ago. It's also the point to double-check what size split system the new install actually needs, rather than simply matching the old unit's capacity.
Frequently Asked Questions
Why do new air conditioners use R32 instead of R410A?
Australia phases down how much high-global-warming-potential HFC refrigerant can be imported each year under the Ozone Protection and Synthetic Greenhouse Gas Management Act 1989, administered by DCCEEW. From 1 July 2025 it also became illegal to import or manufacture small split and multi-head air conditioning systems designed to run on a refrigerant with a GWP over 750 — which rules out R410A (GWP 2,088). R32 has a GWP of 675, so it qualifies, and manufacturers shifted almost all new residential split systems to it well before the ban took effect.
Is R32 refrigerant safe to have in my home?
Yes. R32 is classified A2L under AS/NZS ISO 817, meaning it's mildly flammable and lower in toxicity, not the same risk profile as LPG or a high-flammability gas. Correctly designed, installed, and charged by a licensed technician to Australian Standards, an R32 split system carries no greater everyday risk to a household than the R410A system it replaced.
Do I need to replace my existing R410A air conditioner because of the phase-down?
No. The phase-down and the 1 July 2025 restrictions apply to what can be newly imported or manufactured, not to equipment already installed and running. An existing R410A system can keep being serviced, regassed, and repaired as normal for the rest of its working life; you only encounter R32 when you're buying a new unit.
Can a technician just top up my R410A system with R32 refrigerant?
No. R32 is not a drop-in replacement for R410A. Refrigerant charging rules that came into force on 1 January 2020 make it illegal to charge equipment with a refrigerant it wasn't designed for, and physically the two gases behave differently under pressure. A system designed for R410A must be regassed with R410A, or replaced outright with an R32-rated unit.
Installing or Servicing a Split System in Adelaide?
Our licensed technicians install every major R32-ready brand and can advise on the right system for your home, same-day.
Sources referenced: DCCEEW's hydrofluorocarbon (HFC) phase-down and 1 July 2025 cleaner-cooling rules (dcceew.gov.au), arctick.org's R32 refrigerant technical information for licensed technicians, and AS/NZS ISO 817 refrigerant safety classification.
Disclaimer: This article is provided as general information and guidance only. It draws on publicly available sources, government and industry publications (referenced where relevant), and Voltas Electrical Adelaide's own trade experience — it is not personalised advice for your specific property and does not replace a licensed, on-site assessment. Regulations, pricing, and product or brand details can change over time, so please independently verify anything relevant to your decision and seek your own professional advice before acting. To the fullest extent permitted by law, Voltas Electrical Adelaide accepts no responsibility or liability for any loss, damage, or other outcome arising from reliance on the information in this article. Where this article refers to a same-day or obligation-free quote or assessment, that refers to the quote or assessment itself — a site visit to a property well outside our normal Adelaide metro service area may incur a travel or call-out fee, as set out in our Terms & Conditions, which also has full details on the points above.