If you've read the general comparisons between ducted reverse-cycle and gas heating and already made the call to switch, this guide skips the "which is better" debate and goes straight to the practical sequence: what actually happens to your old gas heater, whether your existing ceiling ductwork can be reused, what your switchboard needs to cope with the new load, and what kind of running-cost change to realistically expect once the conversion is done.
We're a licensed Adelaide air conditioning and electrical business (BLD 274739 · PGE 265145 · AU 61210) that carries out exactly this kind of conversion regularly across Adelaide homes with ageing gas ducted systems, so the steps below reflect what we actually do on site, not a generic checklist.
Step one: decommissioning the old gas ducted heater
The gas heater unit itself — typically located in the roof space or a dedicated cupboard — is disconnected and physically removed once the new reverse-cycle system is ready to go in. This isn't purely an air conditioning contractor's job: the gas supply line that fed the old heater must be safely and permanently capped off by a licensed gasfitter, in line with the gas fitting regulations that apply in South Australia. This step matters for two reasons. First, a gas line left live but disconnected at the appliance end is a genuine safety hazard. Second, if you're claiming any energy efficiency scheme incentive tied to the conversion, proper decommissioning documentation is often a condition of that claim, separate to the air conditioning installation itself.
If your home has other gas appliances staying in place — a gas cooktop or a gas hot water system, for example — only the heater's dedicated line is capped, and the rest of your gas supply and metering continues as normal. It's only once every gas appliance in the home is gone that it makes sense to have the gas connection itself removed and the ongoing daily supply charge eliminated.
Step two: what happens to your existing ductwork
This is usually the first question homeowners ask, and the honest answer is "it depends, but often yes." Many Adelaide homes built with ducted gas heating already have a reasonably comprehensive network of ceiling ducts and outlets running to each room, and in a genuinely significant number of cases, a licensed installer can reuse or adapt that existing ductwork for the new reverse-cycle system rather than reinstalling from scratch — which materially reduces both cost and the amount of ceiling access work required.
What actually gets assessed on-site includes:
- Duct condition and age. Flexible ducting has a working life, and ducts that are crushed, torn, or poorly insulated from age won't perform well on a new system regardless of how good the new unit is.
- Duct sizing versus the new unit's airflow. Reverse-cycle systems don't always have identical airflow characteristics to the gas heater they're replacing, particularly once cooling is added to the same ductwork (a gas ducted heater is heating-only, so its ducting was never sized with summer cooling airflow in mind). Undersized or mismatched ducting shows up as weak airflow to some rooms and can affect the new system's efficiency.
- Register and outlet placement. Existing ceiling outlet positions are often kept as-is if they're already in sensible locations, though some rooms may benefit from an additional or repositioned outlet once cooling airflow is part of the picture, not just heating.
A proper on-site inspection before quoting is the only reliable way to know how much of your existing ductwork will carry over versus what needs replacing — it genuinely varies house to house, and any quote given without that inspection is guesswork.
Want to know exactly how much of your existing ductwork can be reused before committing to a full system replacement?
Get a Same-Day QuoteStep three: switchboard and electrical capacity
A gas ducted heater's own electrical draw is fairly modest — it's essentially running a fan motor and some basic control electronics, since the actual heat comes from burning gas rather than from electricity. A reverse-cycle ducted system replacing it is a genuinely different electrical load: it's running a compressor and fan motors to move heat both ways, year-round, and larger systems sized to heat and cool an entire home can draw considerably more continuous current than the old heater ever did.
Before installation, a licensed electrician needs to confirm the existing switchboard has a suitable spare circuit breaker position rated correctly for the new unit, and more broadly, that the board's overall capacity and condition can safely take on the additional continuous load without exceeding what the incoming supply and existing wiring were designed for. On older switchboards — particularly ones that still have ceramic fuses rather than modern circuit breakers, or limited spare capacity — this step can mean a broader switchboard upgrade is needed alongside the new dedicated circuit, which is worth budgeting for as part of the overall conversion rather than a surprise add-on discovered mid-installation. Our electrical repair and fault-finding and air conditioner installation teams coordinate this assessment together so the electrical and mechanical sides of the job are scoped as one project, not two separate surprises.
Realistic running-cost expectations
Running-cost comparisons between gas and reverse-cycle heating depend heavily on your specific electricity and gas tariffs, how well-insulated the home is, and how the system is actually used day to day — so treat any specific dollar figure as a guide rather than a guarantee for your household. That said, the general direction is consistent and well documented: reverse-cycle heating moves several units of heat energy for every one unit of electricity it consumes, which is fundamentally more efficient than burning gas to generate heat directly, and removing the fixed daily gas supply charge once the last gas appliance is disconnected removes a cost that exists on your bill whether you use much gas or not.
The most reliable way to estimate your own likely saving is to compare your actual current gas heating usage from recent winter bills against the expected electricity draw of a correctly sized replacement system — a conversation worth having directly with your installer rather than relying on a generic national average, since Adelaide's climate, tariff structure, and typical home construction differ from other cities.
If you're weighing this decision up in more general terms first, our broader ducted reverse-cycle vs gas heating comparison and reverse-cycle air conditioning guide are useful background reading, and our radiant vs convection heaters guide is a helpful comparison if you're also weighing up supplementary heating options for one or two rooms rather than whole-home ducted heating.
Choosing the right system and installer for the conversion
Because this is a conversion rather than a like-for-like replacement, correct sizing matters more than it would for a straight system swap. An installer needs to size the new reverse-cycle system against your home's actual heating and cooling load — not simply match the old gas heater's rated output — while also accounting for whatever ductwork is being reused. We install and service the major reverse-cycle brands used across Adelaide ducted systems, including Daikin, Mitsubishi Electric, Fujitsu General, Panasonic, and the other trusted brands we support, and we've carried out this exact gas-to-electric ducted conversion for homeowners in Highgate and Malvern, where established homes with ageing gas ducted systems are common.
Frequently Asked Questions
Can I reuse my existing gas ducted heating ductwork for reverse-cycle air conditioning?
In many Adelaide homes, yes — the existing duct runs and ceiling outlets can often be reused or adapted for a reverse-cycle ducted system, which keeps costs down and avoids reopening ceilings throughout the house. Whether the existing ductwork is suitable depends on its age, condition, sizing relative to the new unit's airflow requirements, and duct insulation, so a site inspection is needed before assuming a full reuse is possible.
Does the old gas line need to be capped by a licensed gasfitter?
Yes. Once a gas ducted heater is removed, the gas supply line feeding it must be safely capped off by a licensed gasfitter — this isn't optional, and it isn't something an air conditioning installer or electrician is licensed to do themselves. If you're keeping other gas appliances such as a gas cooktop or gas hot water system running, only the redundant heater line is capped, not the whole gas supply.
Will my switchboard need upgrading to add a reverse-cycle ducted system?
It depends on the size of the new system and the existing switchboard's spare capacity. A ducted reverse-cycle system sized to heat and cool an entire home draws considerably more continuous power than the fan-only electrical load of a gas ducted heater, so many older switchboards need at least a new dedicated circuit and, in some cases, a broader capacity upgrade to safely accommodate it under AS/NZS 3000.
Will switching from gas to reverse-cycle electric heating actually reduce my running costs?
For most Adelaide homes, yes, though the exact saving depends on your electricity and gas tariffs, home insulation, and how the system is used. Reverse-cycle heating is genuinely efficient because it moves existing heat rather than generating it from scratch, and removing the fixed daily gas supply charge entirely once the last gas appliance is gone adds a further ongoing saving on top of the heating running cost itself.
Ready to Make the Switch?
Get a proper on-site assessment of your existing ductwork, switchboard, and the right system size for your home.
Sources referenced include AS/NZS 3000 (Australian/New Zealand Wiring Rules) for switchboard and circuit requirements, and South Australian gas fitting regulations governing licensed decommissioning of redundant gas appliance connections.
Disclaimer: This article is provided as general information and guidance only. It draws on publicly available sources, government and industry publications (referenced where relevant), and Voltas Electrical Adelaide's own trade experience — it is not personalised advice for your specific property and does not replace a licensed, on-site assessment. Regulations, pricing, and product or brand details can change over time, so please independently verify anything relevant to your decision and seek your own professional advice before acting. To the fullest extent permitted by law, Voltas Electrical Adelaide accepts no responsibility or liability for any loss, damage, or other outcome arising from reliance on the information in this article. Where this article refers to a same-day or obligation-free quote or assessment, that refers to the quote or assessment itself — a site visit to a property well outside our normal Adelaide metro service area may incur a travel or call-out fee, as set out in our Terms & Conditions, which also has full details on the points above.